Home / Sources and Method
Sources and Method
What is sourced, what you enter yourself, and how to read the results.
The grain, and the 17.1 conversion
A grain is a unit of mass equal to 1/7,000 of a pound. Water hardness is often reported in grains per gallon (gpg) of calcium carbonate, or in milligrams per liter (mg/L) or parts per million (ppm) as calcium carbonate. This site converts them at 17.1 ppm per gpg. Maryland Geological Survey states that 1 gpg equals 17.118 mg/L. Connecticut Department of Public Health uses the rounded value 17.1 ppm or mg/L per gpg. Penn State Extension and NDSU Extension sometimes round more loosely to about 17 mg/L. The 17.1 factor is the one used in the calculators.
USGS hardness classes
Classification follows the U.S. Geological Survey Water Science School (updated August 24, 2026): 0 to 60 mg/L as calcium carbonate is soft; 61 to 120 mg/L is moderately hard; 121 to 180 mg/L is hard; more than 180 mg/L is very hard. Values are classified with those bounds (60 and below is soft; above 180 is very hard). Some state fact sheets and extension tables insert a "slightly hard" band; those labels are noted on the converter page and are not mixed into the USGS ranges.
Household water use
The starting gallons-per-person figure is 82. That is total domestic per capita use in the United States in 2015, from the USGS report Estimated Use of Water in the United States in 2015 (also summarized in the USGS June 19, 2018 news release). EPA WaterSense, on its Statistics and Facts page, cites that same 82-gallon USGS figure. EPA WaterSense, How We Use Water, states that the average American family uses more than 300 gallons of water per day at home, and that roughly 70 percent of this use occurs indoors. The Statistics and Facts page also states that outdoor water use accounts for more than 30 percent of total household water use on average, and can be as much as 60 percent in arid regions.
The calculators start at 82 gallons per person and at a 70 percent share through the softener, so that outdoor use can be left out when outdoor taps bypass the unit. Both fields are editable. 82 times 0.70 is about 57 gallons; that product is a derived planning number, not a separate official statistic, which is why the two official figures are entered separately rather than hidden as a single default. If you type daily gallons from a water bill, the per-person estimate is not used. EPA WaterSense, Understanding Your Water Bill, likewise points people to their bills, and notes that a family of four at around 82 gallons per person would use around 10,000 gallons in a 30-day period.
Penn State Extension's Water Softening page (updated September 8, 2025) uses 75 gallons per person per day in a sample calculation (75 x 10 gpg x 4 people = 3,000 grains per day). That 75-gallon figure is Penn State's worked example, not the USGS national estimate, and it is not used as this site's default.
Iron adjustment and days between regenerations
The iron multiplier starts at 4 grains per gallon for each 1 ppm of iron, because the University of Minnesota Water Resources Center states that removal of iron with a softener uses about 4 times more sodium than used to remove hard ions. That is the best official-adjacent source located for a numeric factor. It is still a rule of thumb, so the field is editable. Minnesota also states that, in general, water softeners may remove up to 3 mg/L of iron, and that higher levels are often better handled with an iron filter. Penn State Extension cautions that reduced (colorless) iron can be removed by a softener, while red, oxidized iron (exposed to air or chlorine) will clog the resin and should be filtered first.
Days between regenerations start at 4, in the middle of the University of Minnesota Water Resources Center statement that water softeners should be sized to work three to five days without regeneration. EPA WaterSense recommends demand-initiated regeneration (a meter or sensor) rather than a timer that regenerates on a fixed calendar, so that the unit runs only when the capacity has actually been used.
Salt efficiency
The voluntary efficiency rating in NSF/ANSI 44, Section 7, as restated by the DOE Building America Solution Center and by EPA WaterSense, requires a rated salt efficiency of not less than 3,350 grains of total hardness exchange per pound of salt, demand-initiated regeneration, and no more than 5.0 gallons of water per 1,000 grains of hardness removed. NSF/ANSI 44 is the standard for residential cation exchange water softeners regenerated with sodium or potassium chloride. The 3,350 figure is a minimum for that voluntary rating, not a measured average for all installed units. Bag prices and bag sizes are whatever you enter; this site does not invent a market price.
What these tools do not do
They do not test your water, size a unit for peak flow (gallons per minute), recommend a brand, or apply your city's plumbing or discharge rules. They do not decide whether you should soften at all. Results will change if your hardness was measured as something other than calcium carbonate, if iron is oxidized rather than dissolved, or if the softener is programmed differently from the capacity you entered.
Sources
- U.S. Geological Survey, Water Science School: Hardness of Water (updated August 24, 2026)
- U.S. Geological Survey: Estimated Use of Water in the United States in 2015, Circular 1441
- U.S. Geological Survey news release, June 19, 2018: Water Use Across the United States Declines to Levels Not Seen Since 1970
- U.S. EPA WaterSense: Statistics and Facts
- U.S. EPA WaterSense: How We Use Water
- U.S. EPA WaterSense: Understanding Your Water Bill
- U.S. EPA WaterSense: Soften Water Without Wasting It (guide, 2026)
- DOE Building America Solution Center: Water Softeners (NSF/ANSI 44 voluntary efficiency rating)
- NSF: NSF/ANSI 44 Technical Requirements
- Maryland Geological Survey: Hardness
- Connecticut Department of Public Health, Drinking Water Section: Hardness Fact Sheet (August 2017)
- University of Minnesota Water Resources Center: Residential softening
- Penn State Extension: Water Softening (updated September 8, 2025)
- North Dakota State University Extension: Water Softening (Ion Exchange), WQ1031 (revised May 2022)